  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 36
!
CAUTION
All electrical wiring troubleshooting should be
performed by a qualified electrician in accordance
with local electrical codes.
!
CAUTION
Prior to troubleshooting any equipment, read the
Installation and Operation Manuals for each piece of
equipment to be serviced.
!
WARNING
All electrical/mechanical troubleshooting should be
performed by a qualified electrical/maintenance
individual familiar with UAS equipment.
PROBLEM POSSIBLE CAUSES RECOMMENDED SOLUTIONS
Motor/blower won’t start or Blower rotation is running in reverse. Reverse blower rotation (refer to Section 5.1).
won’t stay running.
Supply power not operational. Check input power to motor circuits for proper
voltage on all legs.
Improper electrical wiring. Check and correct internal motor wiring for proper
connections based on the incoming line voltage.
Check control voltage power supply (i.e., fuses,
transformer, etc.).
Starter overloads tripped. Check for proper motor starter overload rating
against full load amps on motor nameplate. Adjust
or replace overloads as required.
Hopper discharge open to Ensure drum is properly sealed against drum lid
atmosphere. package. Ensure drum lid package is properly
installed (refer to Figure 17).
Blower damper not properly adjusted. Check motor current draw and close volumetric
control damper or silencer damper until amperage
draw is below full load rating of motor.
Dust emissions from clean Filters not installed properly. Inspect and reinstall cartridge filters (refer to
air discharge. Section 6).
Filters are damaged. Replace damaged filter(s) with new Supra-Max
series cartridge filter(s).
Filter access doors not installed Remove and reinstall QuickSeal filter access door
properly. assembly (refer to Figure 19 and Section 6).
New filters are not seasoned or Allow filters to seed during normal operation or
pre-seeded. pre-seed cartridge filters (refer to Section 6.2).
Insufficient airflow. Blower rotation is running in reverse. Reverse blower rotation (refer to Section 5.1).
Loose or open access. Remove QuickSeal filter access door assembly,
verify filters are properly installed and reinstall door
assembly (refer to Section 6.1 and Figure 19). Verify
drum lid is installed properly (refer to Figure 17).
Volumetric duct dampers or blower Adjust dampers to allow for sufficient air volume
outlet damper is not positioned (refer to Sections 5.1 and 5.2).
properly.
Air inlet(s) obstructed. Inspect and clean all hoods and other machine
connections.
Filters plugged. Refer to troubleshooting procedures for continual
pressure drop.
33
United Air Specialists, Inc.
Supra-Blast
Cartridge Dust Collector
Revised 02/02
7. TROUBLESHOOTING GUIDE
Use the troubleshooting guide to correct any problems
that occur with your dust collection unit. If the problem or
condition continues, contact the nearest UAS customer
service office listed on the back cover of this manual.