supply interconnecting signal cord and mounting
hardware for remote blower start/stop assembly
installation. Remove jumper between terminals L and 20
in the combination magnetic motor/blower starter control
package as shown in Figure 11, 12 or 13.
5. OPERATION
5.1 START-UP
Inspect the installation area and make certain no tools,
parts, etc., have been left anywhere on or inside the
Supra-Blast unit. Check blower discharge to make
certain it is free from all debris.
Start motor/blower and check for proper rotation. A
rotation arrow is located on the blower housing. All top-
mount blower assemblies rotate in a clockwise rotation as
viewed from the driven end (motor end with motor cooling
fan). If the blower is rotating in the opposite direction,
disconnect the power to the motor starter. For 3-phase
blowers, interchange any two power wires to the motor at
the load side of the motor starter contactor. For single-
phase power, refer to motor nameplate for which two
wires to interchange at motor junction box. Engage
starter disconnect, start blower and recheck rotation.
NOTE: Proper blower rotation is required to move the
designed amount of air. A blower rotating in the
incorrect direction will only move about 40% of
design airflow.
NOTE: It is important that the air volume of the dust
collection system is at design conditions at
system start-up. There is a minimal pressure
differential across new cartridge filters. If the
volume control damper is not correctly
adjusted, the air volume will be above design
conditions for airflow and may affect the
cartridge filter life.
The air volume should be adjusted based on the
performance of the entire system. Air volume control
damper adjusted to the system design conditions.
Closing the volume control damper decreases system
airflow. Opening the volume control damper increases
system airflow.
On certain applications, it may be beneficial to “seed” or
pre-coat the original or replacement cartridge filters. This
process introduces a certain amount of coating
particulate (usually crushed limestone, agricultural lime or
other specifically marketed pre-coat) in light
concentration to deposit a thin coating of material which
acts as an aid to filtration. This deposited dust cake keeps
the dust loading on the surface of the cartridge filter. This
process will increase filter life and efficiency while
allowing the cleaning system to operate more effectively.
For filter seeding procedures, refer to Section 6.2.
Turn on the compressed air supply to the dust collector
air manifold reservoir. Adjust the pressure regulator until
the gauge reads 90-110 PSIG (6.2-7.6 BAR).
5.2 CHECKLIST
Check the discharge of the blower assembly. Initially,
some dust may discharge from the blower assembly as
the filters are seasoned. This may last several minutes
after which the discharge air should remain visibly clean.
Measure the total airflow and static pressure at the inlet
to the Supra-Blast unit. Adjust the blower outlet damper
for the desired airflow. Check to ensure that adequate
air is being drawn into each of the collection points of
the system. Adjust the individual dampers for each
operation to balance the system airflow. Recheck the
total system airflow and adjust the blower damper to
desired system airflow. This procedure may need to be
repeated several times until the entire system is within
system design airflow specifications.
!
CAUTION
Verify dust collector system airflow is adjusted to design
conditions with a new, clean filter using the volume control
dampers installed in the system. Failure to properly
adjust system airflow may affect cartridge filter life.
27
United Air Specialists, Inc.
Supra-Blast
Cartridge Dust Collector
Revised 02/02
!
CAUTION
Shut off unit disconnect and lock out all electrical power
to the dust collector prior to performing service work.
!
CAUTION
Prior to unit start-up, all installation set-up instructions
must be completed as specified by this manual, the
Supra-Clean
Installation and Operation Manual
,
Supra-View
Installation and Operation Manual
, Supra-
I.Q.
Installation and Operation Manual
, as well as any
manuals supplied by other equipment manufacturers,
as they apply to your dust collector.
!
CAUTION
The blower assembly provided by United Air
Specialists, Inc. includes an outlet damper. If the
blower assembly was purchased separately, ensure a
volume control damper is included somewhere in the
dust collection system. Close the blower discharge
damper to the 50% open position and tighten in place.
If a volume control damper is provided in another part
of the dust collection system, adjust second damper
to the 50% open position and tighten in place.