Page 1 - Cartridge Dust Collector

Supra-BlastCartridge Dust CollectorInstallation and Operation Manual

Page 2

6United Air Specialists, Inc.Supra-BlastCartridge Dust CollectorRevised 02/02Figure 3. Supra-Blast SBD Typical Installation Diagram44-10003-0001, REV

Page 3 - TABLE OF CONTENTS

7United Air Specialists, Inc.Supra-BlastCartridge Dust CollectorRevised 02/02Figure 4. Recommended Unit Clearances44-10007-0001

Page 4

8United Air Specialists, Inc.Supra-BlastCartridge Dust CollectorRevised 02/02In the case of spark producing processes, systemdesign should incorporate

Page 5 - 2. INTRODUCTION

9United Air Specialists, Inc.Supra-BlastCartridge Dust CollectorRevised 02/02Figure 5. Leg Assembly DetailsFIELD_INSTALL_DWG1/SUPRABLAST/SALES/FIELD_I

Page 6 - 2.4 FILTER CLEANING CYCLE

10United Air Specialists, Inc.Supra-BlastCartridge Dust CollectorRevised 02/02Figure 6. Leg Brace Assembly DetailsFIELD_INSTALL_DWG1/SUPRABLAST/SALES/

Page 7

11United Air Specialists, Inc.Supra-BlastCartridge Dust CollectorRevised 02/02NOTE: Each hopper assembly is equipped with four 1/2"(13 mm) pry lo

Page 8 - 4. INSTALLATION

12United Air Specialists, Inc.Supra-BlastCartridge Dust CollectorRevised 02/02with the hardware provided. Secure leg assemblies tothe concrete mountin

Page 9

13United Air Specialists, Inc.Supra-BlastCartridge Dust CollectorRevised 02/02Figure 7. Hopper Assembly DetailsFIELD_INSTALL_DWG1/SUPRABLAST/SALES/FIE

Page 10 - United Air Specialists, Inc

14United Air Specialists, Inc.Supra-BlastCartridge Dust CollectorRevised 02/02Figure 8. Module to Hopper Assembly DetailsFIELD_INSTALL_DWG1/SUPRABLAST

Page 11

15United Air Specialists, Inc.Supra-BlastCartridge Dust CollectorRevised 02/02Figure 9. Multiple Filter Module Section Assembly DetailsFIELD_INSTALL_D

Page 13

16United Air Specialists, Inc.Supra-BlastCartridge Dust CollectorRevised 02/02Figure 10. Top-Mount Blower Support Leg Assembly44-10064-0001

Page 14

17United Air Specialists, Inc.Supra-BlastCartridge Dust CollectorRevised 02/02Figure 11. Power and Elementary Wiring for Units with Supra-Clean Timerb

Page 15 - PANEL INSTALLATION

18United Air Specialists, Inc.Supra-BlastCartridge Dust CollectorRevised 02/02Figure 12. Power and Elementary Wiring for Units with Supra-View Panel44

Page 16 - Installation

19United Air Specialists, Inc.Supra-BlastCartridge Dust CollectorRevised 02/02Figure 13. Power and Elementary Wiring for Units with Supra-I.Q. Diagnos

Page 17

20United Air Specialists, Inc.Supra-BlastCartridge Dust CollectorRevised 02/02Figure 14. Solenoid Wiring to Pulse Controls61-10004-000104-2554, REV C

Page 18

multiple module solenoid valve enclosures with heatersare installed, daisy chain the wiring so that each heaterwill have 100/115/VAC, 50/60 Hz at all

Page 19

Figure 15. Pneumatic Valve Assembly44-10042-000122United Air Specialists, Inc.Supra-BlastCartridge Dust CollectorRevised 02/02

Page 20

Figure 16. Abrasive Inlet Installation44-10045-000123United Air Specialists, Inc.Supra-BlastCartridge Dust CollectorRevised 02/02

Page 21

ROTARY AIR LOCK INSTALLATIONIf a rotary air lock was ordered with the unit, the hopperdischarge will have an adapter already bolted to it. Makecertain

Page 22

If a drum lid latch kit was ordered, attach the separateclamp band around the 55-gallon (208 liter) drum or30-gallon (114 liter) short drum, leaving t

Page 23

TABLE OF CONTENTSPage1. IMPORTANT NOTICE ... 11.1 General Caution

Page 24

Figure 18. Supra-Blast Typical Pressure Gauge Installation44-10043-0001, REV A26United Air Specialists, Inc.Supra-BlastCartridge Dust CollectorRevised

Page 25

supply interconnecting signal cord and mountinghardware for remote blower start/stop assemblyinstallation. Remove jumper between terminals L and 20in

Page 26

Check the differential pressure reading across thedust collector clean to dirty air sections. A normaldifferential pressure drop reading is between 1&

Page 27

PHOTOHELIC GUAGE CONTROL WITHSUPRA-CLEAN TIMERBOARDWhen using a Photohelic Guage with Supra-Cleantimerboard, the timerboard is set to “PS” pulse mode(

Page 28 - ROTARY AIR LOCK INSTALLATION

Figure 19. QuickSeal Filter Access Door and Supra-Max Series Filter Installation44-10006-000130United Air Specialists, Inc.Supra-BlastCartridge Dust C

Page 29

TO REPLACE CARTRIDGE FILTERS(refer to Figure 19):1. Read and follow caution instructions in Section 6before servicing dust collector. Start with the t

Page 30

gate, close the slide gate before servicing the duststorage drum(s). The dust collector fan and compressedair cleaning systems do not have to be turne

Page 31 - 5. OPERATION

!CAUTIONAll electrical wiring troubleshooting should beperformed by a qualified electrician in accordancewith local electrical codes.!CAUTIONPrior to

Page 32

Continual, excessive pressure Compressed air supply problems. Check incoming compressed air for proper supply atdrop (over 7" [178 mm]) on filter

Page 33 - 6. SERVICE

8. ILLUSTRATED PARTSDUST-HOG® Supra-Blast Series44-10009-000135United Air Specialists, Inc.Supra-BlastCartridge Dust CollectorRevised 02/02

Page 35

Supra-Blast Series Dust Collector Bill of MaterialsItem Part No. Description1 33-10001-XXXX Supra-Max Series Cartridge Filter (refer to Section 6.7 fo

Page 38 - (CONTINUED)

UNITED AIR SPECIALISTS, INC.LIMITED WARRANTYUAS warrants all equipment manufactured and sold by UAS against defective parts and workmanship for oneyea

Page 39 - 8. ILLUSTRATED PARTS

To Order Genuine Supra-Blast Replacement Partsand Supra-Max Series Replacement Filters,Contact the Nearest United Air Specialists Office.United Air Sp

Page 40

1United Air Specialists, Inc.Supra-BlastCartridge Dust CollectorRevised 02/021. IMPORTANT NOTICEThis manual contains important safety information andp

Page 41

2United Air Specialists, Inc.Supra-BlastCartridge Dust CollectorRevised 02/02EXAMPLE: SBD 24-3-H55SBD – DUST-HOG Supra-Blast double-filterconfiguratio

Page 42

3United Air Specialists, Inc.Supra-BlastCartridge Dust CollectorRevised 02/02Figure 1. Supra-Blast Air Filter Operation & Cleaning44-10001-0001

Page 43 - LIMITED WARRANTY

4United Air Specialists, Inc.Supra-BlastCartridge Dust CollectorRevised 02/023. SPECIFICATION TABLE4. INSTALLATION4.1 OFF LOADING AND INSPECTIONSupra-

Page 44

5United Air Specialists, Inc.Supra-BlastCartridge Dust CollectorRevised 02/02Figure 2. Supra-Blast SBS Typical Installation Diagram44-10044-0001, REV

Comments to this Manuals

No comments