ROTARY AIR LOCK INSTALLATION
If a rotary air lock was ordered with the unit, the hopper
discharge will have an adapter already bolted to it. Make
certain the bolts connecting the adapter to the hopper
discharge are securely tightened.
Remove all packing from the rotary air lock and
determine its appropriate position. Keep in mind
required clearances, electrical connections and
maintenance. Apply sealant to the flange of the rotary
air lock and fasten to the adapter using M10 bolts,
washers and lock washers.
ABRASIVE INLET INSTALLATION
The abrasive inlet is designed to use the front access
panel(s) of the Supra-Blast series modules as the inlet
area to the unit. There are two styles available - a single
or dual module abrasive inlet. Each is designed to fit
over the appropriate number of front access panels to
serve as a single inlet point for one or two modules
(refer to Figure 16).
Remove the front access panel(s) located above the
QuickSeal filter access doors. Save the hardware. The
hardware will be used to attach the abrasive inlet.
Remove any remaining gasket material from around
the perimeter of the opening.
Apply a 1/4" (6 mm) bead of sealant around the
perimeter of the access opening in a “figure 8” pattern
around the bolt holes. Align the hole pattern on the
abrasive inlet with the hole pattern on the unit and bolt
together using the hardware removed earlier. Fasten the
inlet ductwork securely to the abrasive inlet assembly.
The bottom plate of the abrasive inlet will serve as an
inspection plate. If access to the abrasive inlet is
required, remove and clean out the bottom plate of the
inlet prior to servicing. Do not damage the ribbon of
gasket and reuse after cleaning the gasket surfaces.
DRUM LID INSTALLATION
The drum lid package is an optional accessory for
Supra-Blast series dust collectors.
Remove the drum lid package from its shipping carton.
Place the drum lid on the 55-gallon (208 liter) drum (H55)
or 30-gallon (114 liter) short drum (SD). Slide the 14"
(360 mm) diameter hose over the drum lid and secure
with a hose clamp. Position the drum assembly under the
unit, slide the hose up onto the discharge adapter collar
on the hopper and secure with a hose clamp.
Figure 17. Drum Lid Installation
44-10046-0001
!
CAUTION
The silencer will require a separate support. Do not
use the blower damper or outlet flange to support the
silencer. Apply silicone around the bolt holes of the
connecting flanges, lift the silencer into position and
secure with the hardware provided. Install permanent
supports (customer-supplied) and tighten all hardware
before removing the lifting device.
!
CAUTION
Disconnect all power to the rotary air lock before
servicing. There are moving parts on the rotary air
lock. Do not allow any object to be placed in or near
the rotary air lock during operation.
!
CAUTION
Verify rotary air lock rotation matches rotation arrows
affixed to assembly.
24
United Air Specialists, Inc.
Supra-Blast
Cartridge Dust Collector
Revised 02/02
!
CAUTION
All electrical connections shall be made by a qualified
electrician according to all applicable codes. Refer to
the nameplate and/or documentation for voltage,
amperage, cycle and proper wiring. Refer to rotary air
lock vendor documentation attached with air lock
device.